Runge Masonry: OSHA inspections and violations

Corpus Christi, Texas · Masonry Contractors · NAICS 238140

1inspections
5citation items
$4,000current penalties
Feb 22, 2016last inspection

OSHA inspectors have visited Runge Masonry in Texas one time.

It opened on Feb 22, 2016 as a planned inspection, in Corpus Christi.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $7,600; today they stand at $4,000, 47% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Runge Masonry averages $4,000 across 1 cited inspection.

Runge Masonry: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Runge Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341275691 OPENED FEB 22, 2016Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jan 17, 2018

5217 South Padre Island Dr., Corpus Christi, TX 78411 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$2,000Apr 22, 2016Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$0Apr 22, 2016Final
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$2,000$0Apr 22, 2016Final
Citation 1, item 4a
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$2,000$2,000Apr 22, 2016Final
Citation 1, item 4b
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$0$0Apr 22, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vi)

(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.