OSHA SearchOSHA records by employer

RVC Construction LLC: OSHA inspections and violations

Paramus, New Jersey · Masonry Contractors · NAICS 238140

2inspections
3citation items
$4,800current penalties
Oct 15, 2015last inspection

Since 2015, OSHA inspectors have visited RVC Construction LLC in New Jersey 2 times.

The most recent inspection opened on Oct 15, 2015 as a planned inspection, in Clifton.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $4,800 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. RVC Construction LLC averages $4,800 across 1 cited inspection.

RVC Construction LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch RVC Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340990795 OPENED OCT 15, 2015Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 21, 2019

65 Industrial South, Clifton, NJ 07012 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,000$2,000Dec 21, 2015Final
Citation 1, item 1b
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$0$0Dec 21, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$2,800Dec 21, 2015Final

Inspection 340923747 OPENED SEP 11, 2015Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Sep 21, 2015

181 Midwood Road, Paramus, NJ 07652 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(e)(9)(iv)

(iv) Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.