OSHA SearchOSHA records by employer

Ryan Merrill Masonry: OSHA inspections and violations

North Logan, Utah · Masonry Contractors · NAICS 238140

1inspections
7citation items
$2,025current penalties
Oct 19, 2015last inspection

OSHA has inspected Ryan Merrill Masonry once in Utah.

The inspection began on Oct 19, 2015 as a planned inspection, in North Logan.

That inspection ended with 7 citation items: 7 serious.

Penalties were first proposed at $4,050 and now stand at $2,025, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Ryan Merrill Masonry averages $2,025 (1 cited inspection).

Ryan Merrill Masonry: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Ryan Merrill Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340999838 OPENED OCT 19, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 14, 2016

2855 Naomi Drive, North Logan, UT 84341 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$1,050$525Nov 13, 2015Final
Citation 1, item 1b
29 CFR 1926.405(g)(2) · Job-site wiring
Serious$0$0Nov 13, 2015Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$750Nov 13, 2015Final
Citation 1, item 2b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Nov 13, 2015Final
Citation 1, item 2c
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Nov 13, 2015Final
Citation 1, item 2d
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Nov 13, 2015Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$750Nov 13, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training