S & G Superior, Inc.: OSHA inspections and violations

Brooklyn, New York · Finish Carpentry Contractors · NAICS 238350

2inspections
5citation items
$19,015current penalties
Mar 28, 2018last inspection

S & G Superior, Inc. has 2 OSHA inspections on record in New York, the first in 2017.

OSHA's last visit started on Mar 28, 2018 to follow up on an earlier case, in Brooklyn.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $19,015 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.403, electrical equipment on job sites (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. S & G Superior, Inc. averages $19,015 over 1 cited inspection in that time.

S & G Superior, Inc.: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch S & G Superior, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343046421 OPENED MAR 28, 2018Closed

Follow-up · Partial · Safety · 10 employees at the site · Closed Mar 28, 2018

1460 Fulton Street, Brooklyn, NY 11216 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342364692 OPENED MAY 22, 2017Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jan 11, 2023

1460 Fulton Street, Brooklyn, NY 11216 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$3,803$3,803Aug 4, 2017Final
Citation 1, item 2
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$3,803$3,803Aug 4, 2017Final
Citation 1, item 3
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$3,803$3,803Aug 4, 2017Final
Citation 1, item 4
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$3,803$3,803Aug 4, 2017Final
Citation 1, item 5
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$3,803$3,803Aug 4, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction