OSHA SearchOSHA records by employer

S & R Enterprises, LLC: OSHA inspections and violations

Bel Air, Maryland · Structural Steel and Precast Concrete Contractors · NAICS 238120

4inspections
12citation items
$10,337current penalties
Sep 13, 2019last inspection

S & R Enterprises, LLC has 4 OSHA inspections on record in Maryland, the first in 2006.

OSHA's last visit started on Sep 13, 2019 after an accident, in Owings.

Across those inspections OSHA issued 12 citation items: 3 serious and 9 other-than-serious.

OSHA proposed $15,900 in penalties. After settlements and reviews the total is $10,337, down 35%.

Most often, OSHA cited 1926.757, open web steel joists (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. S & R Enterprises, LLC averages $7,200 over 1 cited inspection in that time.

S & R Enterprises, LLC: OSHA citation items per year, 2006 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch S & R Enterprises, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344305602 OPENED SEP 13, 2019Closed

Accident · Partial · Safety · 5 employees at the site · Closed Oct 22, 2020

2950 Chaneyville Road, Owings, MD 20736 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 11, 2019: Employee incurs multiple facial fractures and injures spleen

At 12:45 p.m. on September 11, 2019, Employee #1 and a coworker, both connectors, were setting 8, 24K7 open web steel ceiling joists spanning 30 feet 2-3/4 inches in bathrooms being constructed for the Mary Harrison Center. According to employee interviews, after the joists were set, Employee #1 and his coworker worked from and anchored their personal fall arrest harnesses to the joists to receive two bundles of metal decking with a combined weight of 6,094 pounds. The coworker, foreman and welder all stated that the joists were not connected to their bearing plates and that they were not bridged before the bundles of decking were landed. After the decking was landed, the joists collapsed bringing Employee #1 and his coworker down with them. Employee #1 sustained multiple facial fractures and an injured spleen, while the coworker was uninjured. Employee #1 was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.757(a)(9) · Open web steel joists
Other-than-serious$3,100$2,100Dec 10, 2019Final
Citation 1, item 2
29 CFR 1926.757(b)(3) · Open web steel joists
Serious$3,100$3,100Dec 10, 2019Final
Citation 1, item 3
29 CFR 1926.757(e)(2) · Open web steel joists
Other-than-serious$3,100$2,000Dec 10, 2019Final

Inspection 312698822 OPENED DEC 3, 2008Closed

Accident · Partial · Safety · 24 employees at the site · Closed Jun 3, 2009

11116 Medical Campus Drive, Hagerstown, MD 21740 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Dec 3, 2008: Employee hospitalized after falling from extension ladder

On December 3, 2008, an ironworker employee was using a Green Bull 32-foot fiber glass extension ladder to reach the grab line on a piece of horizontal steel bea m that was being erected. The grab line was approximately 6 feet long. The emplo yee descended the ladder and fell 2 feet onto the corrugated metal decking. He s uffered a fractured right tibia below the knee and was treated and admitted to t he local hospital. The portable ladder was placed on a vertical upright column, and the side rails were not secured and stabilized on a rigid surface. The ladde r was supported by the rung.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(10) · Ladders in construction
Other-than-serious$2,925$2,925Jan 14, 2009Final

Inspection 309974798 OPENED JUN 29, 2006Closed

Planned · Complete · Safety · 7 employees at the site · Closed Sep 11, 2007

302 National Business Park, Annapolis Junction, MD 20701 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$1,575$0Aug 1, 2006Closed
Citation 1, item 1b
29 CFR 1926.760(a)(1) · Fall protection
Other-than-serious$0$0Aug 1, 2006Closed
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,575$0Aug 1, 2006Closed
Citation 3, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Aug 1, 2006Closed
Citation 3, item 2
29 CFR 1926.502(b)(9) · Fall protection systems
Other-than-serious$0$0Aug 1, 2006Closed

Inspection 310178876 OPENED JUN 21, 2006Closed

Planned · Complete · Safety · 4 employees at the site · Closed Nov 29, 2006

85 Patterson Mill Road, Bel Air, MD 21015 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$525$212Aug 14, 2006Closed
Citation 1, item 2
29 CFR 50405 B01
Other-than-serious$0$0Aug 14, 2006Closed
Citation 1, item 3
29 CFR 50406 A01
Other-than-serious$0$0Aug 14, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(10)

(10) The top of a non-self-supporting ladder shall be placed with the two rails supported equally unless it is equipped with a single support attachment.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.28(a)

(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.757 · Open web steel joists

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.