OSHA SearchOSHA records by employer

S.F Wright Stone Masonry: OSHA inspections and violations

Park City, Utah · Masonry Contractors · NAICS 238140

2inspections
6citation items
$3,000current penalties
Mar 30, 2016last inspection

S.F Wright Stone Masonry has 2 OSHA inspections on record in Utah, the first in 2015.

OSHA's last visit started on Mar 30, 2016 to follow up on an earlier case, in Park City.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $3,000 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. S.F Wright Stone Masonry averages $3,000 over 1 cited inspection in that time.

S.F Wright Stone Masonry: OSHA citation items per year, 2015 to 2016
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch S.F Wright Stone Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341362077 OPENED MAR 30, 2016Closed

Follow-up · Partial · Safety · 3 employees at the site · Closed Mar 31, 2016

502 Ontario Ave, Park City, UT 84060 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341126761 OPENED DEC 15, 2015Closed

Accident · Partial · Safety · 3 employees at the site · Closed Apr 27, 2017

502 Ontario Ave., Park City, UT 84060 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$1,500$1,500Jan 15, 2016Final
Citation 1, item 1b
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$0$0Jan 15, 2016Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jan 15, 2016Final
Citation 1, item 1d
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Jan 15, 2016Final
Citation 1, item 1e
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jan 15, 2016Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$1,500Jan 15, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.