OSHA SearchOSHA records by employer

S-G Construction LLC: OSHA inspections and violations

Castle Rock, Colorado · Siding Contractors · NAICS 238170

1inspections
3citation items
$2,009current penalties
Apr 8, 2023last inspection

OSHA inspectors have visited S-G Construction LLC in Colorado one time.

It opened on Apr 8, 2023 as a planned inspection, in Castle Rock.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $3,349; today they stand at $2,009, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. S-G Construction LLC averages $2,009 across 1 cited inspection.

S-G Construction LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

132employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch S-G Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346624737 OPENED APR 8, 2023Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 17, 2023

519 Coal Bank Trail, Castle Rock, CO 80104 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$3,349$2,009Sep 1, 2023Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 1, 2023Final
Citation 1, item 1c
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Sep 1, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.