OSHA SearchOSHA records by employer

S. Gary Shoemaker Rigging & Transport LLC: OSHA inspections and violations

Mogadore, Ohio · Other Building Equipment Contractors · NAICS 238290

2inspections
19citation items
$15,000current penalties
Mar 12, 2019last inspection

Since 2019, OSHA inspectors have visited S. Gary Shoemaker Rigging & Transport LLC in Ohio 2 times.

The most recent inspection opened on Mar 12, 2019 on a referral, in Mogadore.

In all, OSHA issued 19 citation items: 18 serious and 1 other-than-serious.

The proposed penalties came to $32,583; today they stand at $15,000, 54% less.

The rule cited most here is 1926.1204 (permit-required confined space program), 10 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. S. Gary Shoemaker Rigging & Transport LLC averages $7,500 across 2 cited inspections.

It reported 1 severe injury to OSHA since 2015.

S. Gary Shoemaker Rigging & Transport LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch S. Gary Shoemaker Rigging & Transport LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343841862 OPENED MAR 12, 2019Closed

Referral · Partial · Health · 25 employees at the site · Closed Aug 30, 2019

3555 Gilchrist Rd, Mogadore, OH 44260 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.353(b)(1) · Ventilation and protection in welding, cutting, and heating
Serious$3,789$1,894Jul 5, 2019Final
Citation 1, item 2a
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Serious$3,789$1,895Jul 5, 2019Final
Citation 1, item 2b
29 CFR 1926.1203(b)(1) · Confined Spaces in Construction: general requirements
Serious$0$0Jul 5, 2019Final
Citation 1, item 3a
29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements
Serious$3,789$0Jul 5, 2019Final
Citation 1, item 3b
29 CFR 1926.1204(b) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3c
29 CFR 1926.1204(c) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3d
29 CFR 1926.1204(d) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3e
29 CFR 1926.1204(e)(1) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3f
29 CFR 1926.1204(e)(2) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3g
29 CFR 1926.1204(f) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3h
29 CFR 1926.1204(h) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3i
29 CFR 1926.1204(i) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3j
29 CFR 1926.1204(j) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final
Citation 1, item 3k
29 CFR 1926.1204(l) · Permit-required confined space program
Serious$0$0Jul 5, 2019Final

Inspection 343819348 OPENED FEB 28, 2019Closed

Referral · Complete · Safety · 25 employees at the site · Closed Aug 30, 2019

3555 Gilchrist Road, Mogadore, OH 44260 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

Incident on Feb 23, 2019: Employee falls from scaffold and receives leg and arm fractu

At 4:00 p.m. on February 23, 2019, an employee worked from a scaffold to install metal trim on a new SACMI ATM 36 Spray Dryer for a Ceramic Slip. At some point, the employee fell approximately fifty feet from the scaffold and was hospitalized to treat fractures to the legs and arms and abdominal contusions.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$5,304$4,243Jul 5, 2019Final
Citation 1, item 1b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$5,304$0Jul 5, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$5,304$4,243Jul 5, 2019Final
Citation 1, item 4
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$5,304$2,725Jul 5, 2019Final
Citation 2, item 1
29 CFR 1926.251(b)(6)(ii) · Rigging equipment for material handling
Other-than-serious$0$0Jul 5, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 23, 2019, Mogadore: Hospitalization · avulsions, enucleations · tooth (teeth)

An employee was transferring from an aerial lift to a scaffold platform and fell approximately 50 feet to the ground. The employee suffered two broken legs and the loss of teeth.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(a)

(a) Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.

29 CFR 1926.1203(b)(1)

(1) Inform exposed employees by posting danger signs or by any other equally effective means, of the existence and location of, and the danger posed by, each permit space; and

29 CFR 1926.1203(d)

(d) If any employer decides that employees it directs will enter a permit space, that employer must have a written permit space program that complies with § 1926.1204 implemented at the construction site. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives.

29 CFR 1926.1204 · Permit-required confined space program

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.353 · Ventilation and protection in welding, cutting, and heating

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

Other other building equipment contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.