OSHA SearchOSHA records by employer

S-H Opco Copperfield Village, LLC: OSHA inspections and violations

Victoria, Texas · Assisted Living Facilities for the Elderly · NAICS 623312

1inspections
9citation items
$4,500current penalties
Jan 15, 2019last inspection

OSHA has inspected S-H Opco Copperfield Village, LLC once in Texas.

The inspection began on Jan 15, 2019 as a planned inspection, in Victoria.

That inspection ended with 9 citation items: 7 serious and 2 other-than-serious.

Penalties were first proposed at $12,881 and now stand at $4,500, 65% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for health care employers since 2015 is $1,050, and S-H Opco Copperfield Village, LLC averages $4,500 (1 cited inspection).

S-H Opco Copperfield Village, LLC also files yearly injury logs with OSHA, summarized below.

S-H Opco Copperfield Village, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

404employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch S-H Opco Copperfield Village, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343717187 OPENED JAN 15, 2019Closed

Planned · Complete · Health · 25 employees at the site · Closed Jul 25, 2019

501 E. Larkspur St., Victoria, TX 77904 · Assisted Living Facilities for the Elderly · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$4,546$1,590Feb 15, 2019Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,546$1,590Feb 15, 2019Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Feb 15, 2019Final
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Feb 15, 2019Final
Citation 1, item 2d
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Feb 15, 2019Final
Citation 1, item 3a
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$3,789$1,320Feb 15, 2019Final
Citation 1, item 3b
29 CFR 1910.333(b)(2)(iii) · Working near live electrical parts
Serious$0$0Feb 15, 2019Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 15, 2019Final
Citation 2, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 15, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Victoria site logged 3 recordable injuries or illnesses among about 24 workers: 23.6 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 3 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Copperfield Village
Victoria · 2019
24 3123.61.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.333 · Working near live electrical parts

Other assisted living facilities for the elderly employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.