OSHA SearchOSHA records by employer

S.L. Williamson Company, Inc.: OSHA inspections and violations

Charlottesville, Virginia · Highway, Street, and Bridge Construction · NAICS 237310

8inspections
10citation items
$12,606current penalties
Feb 10, 2021last inspection

S.L. Williamson Company, Inc. has 8 OSHA inspections on record in Virginia, the first in 1988.

OSHA's last visit started on Feb 10, 2021 after a complaint, in Charlottesville.

Across those inspections OSHA issued 10 citation items: 6 serious and 4 other-than-serious.

OSHA proposed $12,906 in penalties. After settlements and reviews the total is $12,606, down 2%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. S.L. Williamson Company, Inc. averages $11,932 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

S.L. Williamson Company, Inc.: OSHA citation items per year, 1988 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

251employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch S.L. Williamson Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345146880 OPENED FEB 10, 2021Closed

Complaint · Partial · Safety · State government · 200 employees at the site · Closed Jan 27, 2023

Intersection Of Gray Fox Trail & Gray Fox Spur, Charlottesville, VA 22902 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 4a
29 CFR 1926.651(b)(4) · Excavations
Serious$11,932$11,932Jan 16, 2023Final
Citation 1, item 4b
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Jan 16, 2023Final
Citation 1, item 4c
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jan 16, 2023Final

Inspection 340068527 OPENED NOV 6, 2014Closed

Fatality or catastrophe · Partial · Safety · State government · 104 employees at the site · Closed Feb 26, 2020

250 Pantops Mountain Road, Charlottesville, VA 22901 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Incident on Nov 6, 2014 (fatal): Employee is run over by vibrating rolling compactor and is k

At approximately 2:15 a.m. on November 6, 2014, an employee was driving a vibrating rolling compactor off of a low-boy tractor trailer. The employee lost control of the vibrating rolling compactor and jumped from the compactor, while still under power to the ground. The compactor landed near the employee and ran over him. The employee received crushing injury to the head and was killed. killed.

No citations from this inspection.

Inspection 306816430 OPENED NOV 3, 2003Closed

Planned · Complete · Safety · 100 employees at the site · Closed Dec 2, 2003

1230 River Road, Charlottesville, VA 22902 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(f)(1) · Exit routes
Serious$375$225Nov 19, 2003Closed
Citation 1, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$375$225Nov 19, 2003Closed
Citation 2, item 1
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Nov 19, 2003Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Nov 19, 2003Closed

Inspection 302590799 OPENED DEC 8, 1998Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 9, 1998

1230 River Road, Charlottesville, VA 22902 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126613009 OPENED AUG 19, 1998Closed

Planned · Complete · Safety · 10 employees at the site · Closed Aug 19, 1998

1230 River Road, Charlottesville, VA 22902 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126603273 OPENED JUL 30, 1997Closed

Referral · Partial · Safety · 5 employees at the site · Closed Oct 6, 1997

2529 Richmond Rd., Charlottesville, VA 22901 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$225$225Aug 14, 1997Closed
Citation 2, item 1
29 CFR ARM000205 A
Other-than-serious$0$0Aug 14, 1997Closed
Citation 2, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Aug 14, 1997Closed

Inspection 125435198 OPENED APR 24, 1997Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 24, 1997

13270 Liberty Road, Gordonsville, VA 22942 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105672075 OPENED AUG 15, 1988Closed

Unprogrammed related · Complete · Safety · 25 employees at the site · Closed Aug 25, 1988

Uva Replacement Hospital, 202 Park Place, Charlottesville, VA 22903 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other highway, street, and bridge construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.