OSHA SearchOSHA records by employer

Saldanas Masonry: OSHA inspections and violations

Brownsville, Texas · Concrete Block and Brick Manufacturing · NAICS 327331

1inspections
2citation items
$600current penalties
Jul 20, 2017last inspection

Saldanas Masonry has one OSHA inspection on record in Texas.

OSHA opened it on Jul 20, 2017 as a planned inspection, in Brownsville.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $2,309 in penalties. After settlements and reviews the total is $600, down 74%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Saldanas Masonry averages $600 over 1 cited inspection in that time.

Saldanas Masonry: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Saldanas Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342485133 OPENED JUL 20, 2017Closed

Planned · Complete · Safety · 10 employees at the site · Closed Nov 19, 2019

3807 N Expressway, Brownsville, TX 78526 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,309$600Oct 26, 2017Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Oct 26, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other concrete block and brick manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.