OSHA SearchOSHA records by employer

Salem RV Center, Incorporated: OSHA inspections and violations

Selinsgrove, Pennsylvania · Recreational Vehicle Dealers · NAICS 441210

1inspections
3citation items
$3,500current penalties
Aug 16, 2016last inspection

OSHA has inspected Salem RV Center, Incorporated once in Pennsylvania.

The inspection began on Aug 16, 2016 after a complaint, in Selinsgrove.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $5,701 and now stand at $3,500, 39% lower after settlements or reviews.

Ladders in general industry comes up most often in these citations: 2 items under 1910.23.

How that compares: the median penalty per cited inspection for retail employers since 2015 is $1,750, and Salem RV Center, Incorporated averages $3,500 (1 cited inspection).

Salem RV Center, Incorporated: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

268employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Salem RV Center, Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341701340 OPENED AUG 16, 2016Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Jul 14, 2017

387 Clifford Road, Selinsgrove, PA 17870 · Recreational Vehicle Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$3,563$2,500Aug 30, 2016Final
Citation 1, item 1b
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$0$0Aug 30, 2016Final
Citation 1, item 2
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$2,138$1,000Aug 30, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(j)(2)(iv)

(iv) A receptacle installed in a wet or damp location shall be suitable for the location.

Other recreational vehicle dealers employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.