OSHA SearchOSHA records by employer

Salvador Prado: OSHA inspections and violations

Belmont, North Carolina · Siding Contractors · NAICS 238170

1inspections
3citation items
$4,500current penalties
Nov 3, 2021last inspection

OSHA has inspected Salvador Prado once in North Carolina.

The inspection began on Nov 3, 2021 as a planned inspection, in Belmont.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $4,500 and still stand at $4,500.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Salvador Prado averages $4,500 (1 cited inspection).

Salvador Prado: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Salvador Prado and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345659908 OPENED NOV 3, 2021Closed

Planned · Partial · Health · 1 employee at the site · Closed Mar 13, 2025

Nixon Road At Rachel Anne Drive, Belmont, NC 28012 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$1,500$1,500Dec 30, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$1,500Dec 30, 2021Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$1,500$1,500Dec 30, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(7)

(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.