Sams Contracting and Remodeling: OSHA inspections and violations

Lansdale, Pennsylvania · Masonry Contractors · NAICS 238140

1inspections
4citation items
$1,080current penalties
Oct 29, 2019last inspection

OSHA inspectors have visited Sams Contracting and Remodeling in Pennsylvania one time.

It opened on Oct 29, 2019 as a planned inspection, in Lansdale.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $1,735; today they stand at $1,080, 38% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sams Contracting and Remodeling averages $1,080 across 1 cited inspection.

Sams Contracting and Remodeling: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Sams Contracting and Remodeling and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344436209 OPENED OCT 29, 2019Closed

Planned · Partial · Safety · 1 employee at the site · Closed Apr 3, 2023

229 W. 5th St., Lansdale, PA 19446 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,735$1,080Feb 18, 2020Final
Citation 1, item 1b
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$0$0Feb 18, 2020Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Feb 18, 2020Final
Citation 1, item 1d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 18, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(1)(ii)

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.