Samuel Gonzalez: OSHA inspections and violations

Pfafftown, North Carolina · Masonry Contractors · NAICS 238140

1inspections
3citation items
$2,400current penalties
Dec 9, 2021last inspection

OSHA inspectors have visited Samuel Gonzalez in North Carolina one time.

It opened on Dec 9, 2021 as a planned inspection, in Pfafftown.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $2,400 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Samuel Gonzalez averages $2,400 across 1 cited inspection.

Samuel Gonzalez: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Samuel Gonzalez again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345680706 OPENED DEC 9, 2021Closed

Planned · Complete · Health · 3 employees at the site · Closed Mar 14, 2025

5547 Glad Acres Rd, Pfafftown, NC 27040 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$1,500$1,500Feb 16, 2022Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$900$900Feb 16, 2022Final
Citation 1, item 2b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 16, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)(vi)

(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).

Other masonry contractors employers in North Carolina