OSHA SearchOSHA records by employer

Sanantonio Construction: OSHA inspections and violations

Rutherford, New Jersey · Masonry Contractors · NAICS 238140

1inspections
4citation items
$6,650current penalties
Sep 9, 2019last inspection

Sanantonio Construction has one OSHA inspection on record in New Jersey.

OSHA opened it on Sep 9, 2019 as a planned inspection, in Rutherford.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $10,230 in penalties. After settlements and reviews the total is $6,650, down 35%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sanantonio Construction averages $6,650 over 1 cited inspection in that time.

Sanantonio Construction: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Sanantonio Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344288949 OPENED SEP 9, 2019Closed

Planned · Partial · Safety · 7 employees at the site · Closed Feb 5, 2021

480 Paterson Ave, Rutherford, NJ 07070 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$2,273$1,477Oct 10, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$2,273$1,477Oct 10, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,842$1,847Oct 10, 2019Final
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,842$1,847Oct 10, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(9)(i)

(i) The employer shall provide safe means of access for each employee erecting or dismantling a scaffold where the provision of safe access is feasible and does not create a greater hazard. The employer shall have a competent person determine whether it is feasible or would pose a greater hazard to provide, and have employees use a safe means of access. This determination shall be based on site conditions and the type of scaffold being erected or dismantled.

29 CFR 1926.451(e)(9)(iv)

(iv) Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in New Jersey