OSHA SearchOSHA records by employer

Sanchez Builders LLC: OSHA inspections and violations

Frisco, Colorado · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
4citation items
$7,258current penalties
Oct 19, 2023last inspection

OSHA has inspected Sanchez Builders LLC once in Colorado.

The inspection began on Oct 19, 2023 after a complaint, in Frisco; the case is still open.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $14,517 and now stand at $7,258, 50% lower after settlements or reviews.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Sanchez Builders LLC averages $7,258 (1 cited inspection).

Sanchez Builders LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Sanchez Builders LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347045536 OPENED OCT 19, 2023Open

Complaint · Partial · Safety · 10 employees at the site · Open

7th Ave And Frisco Street, Frisco, CO 80443 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(k)(1) · Excavations
Serious$4,839$2,420Mar 6, 2024Final
Citation 1, item 1b
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Mar 6, 2024Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$4,839$2,420Mar 6, 2024Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,839$2,420Mar 6, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other poured concrete foundation and structure contractors employers in Colorado

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.