OSHA SearchOSHA records by employer

Sanchez Construction: OSHA inspections and violations

Calera, Alabama · Masonry Contractors · NAICS 238140

1inspections
8citation items
$11,767current penalties
Jun 17, 2026last inspection

OSHA has inspected Sanchez Construction once in Alabama.

The inspection began on Jun 17, 2026 as a planned inspection, in Calera; the case is still open.

That inspection ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $19,612 and now stand at $11,767, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Sanchez Construction averages $11,767 (1 cited inspection).

Sanchez Construction: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Sanchez Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 349007674 OPENED JUN 17, 2026Open

Planned · Partial · Safety · 6 employees at the site · Open

595-613 George Roy Parkway, Calera, AL 35040 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,405$2,043Aug 12, 2026Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$3,972$2,383Aug 12, 2026Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,972$2,383Aug 12, 2026Final
Citation 1, item 4a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$3,972$2,383Aug 12, 2026Final
Citation 1, item 4b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 12, 2026Final
Citation 1, item 5
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,972$2,383Aug 12, 2026Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 12, 2026Final
Citation 2, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$319$191Aug 12, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.454 · Scaffold training