OSHA SearchOSHA records by employer

Sanchez Construction Services, LLC: OSHA inspections and violations

Severn, Maryland · Siding Contractors · NAICS 238170

1inspections
10citation items
$877current penalties
Mar 26, 2018last inspection

Sanchez Construction Services, LLC has one OSHA inspection on record in Maryland.

OSHA opened it on Mar 26, 2018 as a planned inspection, in Severn.

From that inspection OSHA issued 10 citation items: 10 serious.

OSHA proposed $1,950 in penalties. After settlements and reviews the total is $877, down 55%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sanchez Construction Services, LLC averages $877 over 1 cited inspection in that time.

Sanchez Construction Services, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

197employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Sanchez Construction Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343048815 OPENED MAR 26, 2018Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jul 10, 2018

1709 Willard Way, Severn, MD 21144 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$900$405Jun 5, 2018Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$472Jun 5, 2018Final
Citation 1, item 2b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Jun 5, 2018Final
Citation 1, item 2c
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$0$0Jun 5, 2018Final
Citation 1, item 2d
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Jun 5, 2018Final
Citation 1, item 2e
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jun 5, 2018Final
Citation 1, item 2f
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Jun 5, 2018Final
Citation 1, item 2g
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jun 5, 2018Final
Citation 1, item 2h
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jun 5, 2018Final
Citation 1, item 2i
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jun 5, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.454 · Scaffold training

Other siding contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.