OSHA SearchOSHA records by employer

SBF Construction, Inc.: OSHA inspections and violations

Jersey City, New Jersey · Poured Concrete Foundation and Structure Contractors · NAICS 238110

4inspections
14citation items
$96,114current penalties
Jan 24, 2026last inspection

SBF Construction, Inc. has 4 OSHA inspections on record in New Jersey, the first in 2011.

OSHA's last visit started on Jan 24, 2026 after a fatality or catastrophe, in New Brunswick, and the case has not closed yet.

Across those inspections OSHA issued 14 citation items: 13 serious and 1 other-than-serious.

OSHA proposed $101,634 in penalties. After settlements and reviews the total is $96,114, down 5%.

Most often, OSHA cited 1926.55, gases, vapors, fumes, dusts, and mists (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. SBF Construction, Inc. averages $43,917 over 2 cited inspections in that time.

SBF Construction, Inc. also files yearly injury logs with OSHA, summarized below.

SBF Construction, Inc.: OSHA citation items per year, 2011 to 2026
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch SBF Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348711482 OPENED JAN 24, 2026Open

Fatality or catastrophe · Partial · Health · 15 employees at the site · Open

21 Spring St, New Brunswick, NJ 08901 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$14,895$14,895Jul 21, 2026Contested
Citation 1, item 2a
29 CFR 1926.55(a)(2) · Gases, vapors, fumes, dusts, and mists
Serious$14,895$14,895Jul 21, 2026Contested
Citation 1, item 2b
29 CFR 1926.55(b) · Gases, vapors, fumes, dusts, and mists
Serious$0$0Jul 21, 2026Contested
Citation 1, item 3
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Serious$14,895$14,895Jul 21, 2026Contested
Citation 1, item 4
29 CFR 1926.1204(i) · Permit-required confined space program
Serious$14,895$14,895Jul 21, 2026Contested
Citation 1, item 5 Serious$14,895$14,895Jul 21, 2026Contested

Inspection 345192645 OPENED MAR 11, 2021Closed

Referral · Partial · Safety · 2 employees at the site · Closed Apr 28, 2021

25 Christopher Columbus Drive, Jersey City, NJ 07302 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344611736 OPENED FEB 6, 2020Closed

Planned · Partial · Safety · 200 employees at the site · Closed Mar 3, 2021

25 Christopher Columbus Drive, Jersey City, NJ 07302 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Other-than-serious$13,359$13,359Apr 14, 2020Final

Inspection 314679853 OPENED SEP 19, 2011Closed

Referral · Complete · Safety · 13 employees at the site · Closed Dec 9, 2011

28 Grand Avenue (benzel Busch), Englewood, NJ 07631 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.307(d)(1) · Mechanical power-transmission apparatus
Serious$1,800$1,080Nov 10, 2011Closed
Citation 1, item 1b
29 CFR 1926.307(e)(3) · Mechanical power-transmission apparatus
Serious$0$0Nov 10, 2011Closed
Citation 1, item 2a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,200$2,520Nov 10, 2011Closed
Citation 1, item 2b
29 CFR 1926.702(h) · Requirements for equipment and tools
Serious$0$0Nov 10, 2011Closed
Citation 1, item 3
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,000$1,800Nov 10, 2011Closed
Citation 1, item 4
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$3,000$1,800Nov 10, 2011Closed
Citation 1, item 5
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$1,800$1,080Nov 10, 2011Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Jersey City site logged 2 recordable injuries or illnesses among about 209 workers: 1.0 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 5 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Fifty Hudson Street
Jersey City · 2025
209 211.02.8
11 Spring Street
New Brunswick · 2025
209 110.52.8
Journal Square III
Jersey City · 2023
85 101.22.8

Included with any plan: 1 more yearly log from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(a)

(a) Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.

29 CFR 1926.1204 · Permit-required confined space program

29 CFR 1926.1207 · Training

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.55 · Gases, vapors, fumes, dusts, and mists

29 CFR 1926.702 · Requirements for equipment and tools

Other poured concrete foundation and structure contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.