OSHA SearchOSHA records by employer

SC Products, Inc.: OSHA inspections and violations

Eldorado, Illinois · Fabricated Structural Metal Manufacturing · NAICS 332312

4inspections
12citation items
$18,382current penalties
Feb 5, 2018last inspection

OSHA has inspected SC Products, Inc. 4 times in Illinois since 2012.

The latest one began on Feb 5, 2018 after a complaint, in Eldorado.

Those inspections ended with 12 citation items: 10 serious and 2 other-than-serious.

Penalties were first proposed at $34,374 and now stand at $18,382, 47% lower after settlements or reviews.

Slings comes up most often in these citations: 3 items under 1910.184.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and SC Products, Inc. averages $4,191 (2 cited inspections).

SC Products, Inc.: OSHA citation items per year, 2012 to 2018
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

423employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch SC Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342926888 OPENED FEB 5, 2018Closed

Complaint · Partial · Health · 19 employees at the site · Closed Oct 16, 2018

50 Greenhill Road, Eldorado, IL 62930 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(6) · Exit routes
Serious$3,326$2,328Jun 13, 2018Final
Citation 1, item 2
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$3,326$2,328Jun 13, 2018Final
Citation 2, item 1 Other-than-serious$0$0Jun 13, 2018Final

Inspection 342927605 OPENED FEB 5, 2018Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Oct 16, 2018

50 Greenhill Road, Eldorado, IL 62930 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,661$1,863Jun 13, 2018Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Serious$2,661$1,863Jun 13, 2018Final

Inspection 339054009 OPENED MAY 8, 2013Closed

Follow-up · Partial · Health · 15 employees at the site · Closed Sep 27, 2013

50 Greenhill Road, Eldorado, IL 62930 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 332427467 OPENED FEB 28, 2012Closed

Complaint · Partial · Health · 30 employees at the site · Closed Dec 12, 2013

50 Greenhill Road, Eldorado, IL 62930 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$4,900$2,500May 9, 2012Final
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$2,800$0May 9, 2012Final
Citation 1, item 3
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,900$2,500May 9, 2012Final
Citation 1, item 4a Serious$4,200$2,150May 9, 2012Final
Citation 1, item 4b Serious$0$0May 9, 2012Final
Citation 1, item 5 Serious$2,800$1,425May 9, 2012Final
Citation 1, item 6
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,800$1,425May 9, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.184 · Slings

29 CFR 1910.184(c)(1)

(1) Slings that are damaged or defective shall not be used.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise