OSHA SearchOSHA records by employer

Schleifring Medical Systems, LLC: OSHA inspections and violations

Elgin, Illinois · Electromedical and Electrotherapeutic Apparatus Manufacturing · NAICS 334510

1inspections
2citation items
$15,000current penalties
Nov 9, 2022last inspection

Schleifring Medical Systems, LLC has one OSHA inspection on record in Illinois.

OSHA opened it on Nov 9, 2022 on a referral, in Elgin.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $21,876 in penalties. After settlements and reviews the total is $15,000, down 31%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Schleifring Medical Systems, LLC averages $15,000 over 1 cited inspection in that time.

Schleifring Medical Systems, LLC also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Schleifring Medical Systems, LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Schleifring Medical Systems, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346337140 OPENED NOV 9, 2022Closed

Referral · Partial · Safety · 75 employees at the site · Closed Jul 10, 2023

1420 Crispin Dr., Elgin, IL 60123 · Electromedical and Electrotherapeutic Apparatus Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$10,938$7,500Mar 17, 2023Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$10,938$7,500Mar 17, 2023Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Elgin site logged 5 recordable injuries or illnesses among about 69 workers: 7.5 per 100 full-time workers, against a median of 0.3 for its industry. Those cases cost 180 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
GEHC Elgin IL
Elgin · 2025
69 517.50.3
GEHC : Elgin, IL
Elgin · 2024
74 000.00.3

Included with any plan: 2 more yearly logs from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

May 28, 2025, Elgin: Hospitalization · fractures · elbow(s)

On May 28, 2025, two maintenance employees were working on a flipper mechanism that was intermittently getting stuck during its vertical movement cycle. An employee began removing the bottom motor of the flipper assembly. The gearbox unexpectedly detached along with the motor. This caused the flipper arm (weighing ~250 pounds) to lose mechanical support and fall, striking an employee. The flipper…

Oct 31, 2022, Elgin: Hospitalization, amputation · amputations · fingertip(s)

An employee's glove was caught on the rotating spindle of a computer numerical control (CNC) machine, resulting in the amputation of two fingertips and a broken finger.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

Other electromedical and electrotherapeutic apparatus manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.