OSHA SearchOSHA records by employer

Schurman Construction, LLC: OSHA inspections and violations

Lynchburg, Ohio · Roofing Contractors · NAICS 238160

3inspections
12citation items
$12,000current penalties
Sep 11, 2015last inspection

Schurman Construction, LLC has 3 OSHA inspections on record in Ohio, the first in 1999.

OSHA's last visit started on Sep 11, 2015 on a referral, in Lynchburg.

Across those inspections OSHA issued 12 citation items: 12 serious.

OSHA proposed $14,900 in penalties. After settlements and reviews the total is $12,000, down 19%.

Most often, OSHA cited 1926.1101, asbestos in construction (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Schurman Construction, LLC averages $5,200 over 2 cited inspections in that time.

Schurman Construction, LLC: OSHA citation items per year, 1999 to 2015
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

273employers cited

73 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Schurman Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340913326 OPENED SEP 11, 2015Closed

Referral · Partial · Health · 4 employees at the site · Closed Jan 23, 2019

271 Broadway Street, Lynchburg, OH 45142 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$2,800$2,800Feb 8, 2016Final
Citation 1, item 1b
29 CFR 1926.1101(h)(2)(i) · Asbestos in construction
Serious$0$0Feb 8, 2016Final
Citation 1, item 2a
29 CFR 1926.1101(f)(1)(i) · Asbestos in construction
Serious$2,800$2,800Feb 8, 2016Final
Citation 1, item 2b
29 CFR 1926.1101(g)(7)(i) · Asbestos in construction
Serious$0$0Feb 8, 2016Final
Citation 1, item 2c
29 CFR 1926.1101(g)(8)(ii) · Asbestos in construction
Serious$0$0Feb 8, 2016Final
Citation 1, item 2d
29 CFR 1926.1101(k)(9)(i) · Asbestos in construction
Serious$0$0Feb 8, 2016Final
Citation 1, item 2e
29 CFR 1926.1101(k)(9)(iv)(a) · Asbestos in construction
Serious$0$0Feb 8, 2016Final

Inspection 340914456 OPENED SEP 11, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 10, 2019

271 Broadway St., Lynchburg, OH 45142 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,800$2,800Oct 8, 2015Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,000$2,000Oct 8, 2015Final

Inspection 103227229 OPENED JUN 16, 1999Closed

Planned · Partial · Safety · 2 employees at the site · Closed May 30, 2000

302 Mulberry St., Lebanon, OH 45036 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$600Jun 23, 1999Closed
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,500$500Jun 23, 1999Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$500Jun 23, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.1101(f)(1)(i)

(f) Exposure assessments and monitoring—(1) General monitoring criteria. (i) Each employer who has a workplace or work operation where exposure monitoring is required under this section shall perform monitoring to determine accurately the airborne concentrations of asbestos to which employees may be exposed.

29 CFR 1926.1101(g)(7)(i)

(7) Work practices and engineering controls for Class II work. (i) All Class II work shall be supervised by a competent person as defined in paragraph (b) of this section.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.