Inspection 342398427 OPENED JUN 14, 2017Closed
Corner Of 7th And South Street, Petal, MS 39465 · Machine Shops · OSHA's record · Phone and website on Google Maps
Incident on Jun 13, 2017 (fatal): Two employees are killed while replacing a pump
At 2:00 p.m. on June 13, 2017, two employees, a father and son team, were replacing a pump. The son was overcome by hydrogen sulfide gas and became unconscious. As the father retrieved his son from the pump lift station, he fell and a suffered blunt force trauma injury. Both father and son died.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.50(c) · Medical services and first aid |
Serious | $3,259 | $1,960 | Nov 3, 2017 | Final |
| Citation 1, item 2a 29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |
| Citation 1, item 2b 29 CFR 1926.1204(b) · Permit-required confined space program |
Serious | $0 | $0 | Nov 3, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.1204(c) · Permit-required confined space program |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |
| Citation 1, item 4 29 CFR 1926.1204(d)(1) · Permit-required confined space program |
Serious | $12,675 | $9,600 | Nov 3, 2017 | Final |
| Citation 1, item 5 29 CFR 1926.1204(d)(4) · Permit-required confined space program |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |
| Citation 1, item 6 29 CFR 1926.1204(d)(7) · Permit-required confined space program |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |
| Citation 1, item 7 29 CFR 1926.1204(d)(8) · Permit-required confined space program |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |
| Citation 1, item 8 29 CFR 1926.1205(a) · Permitting process |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |
| Citation 1, item 9 29 CFR 1926.1207(a) · Training |
Serious | $3,803 | $2,300 | Nov 3, 2017 | Final |