OSHA SearchOSHA records by employer

Scorpion Protective Coatings Inc: OSHA inspections and violations

Cloverdale, Indiana · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · NAICS 332812

2inspections
10citation items
$2,160current penalties
Feb 9, 2021last inspection

Scorpion Protective Coatings Inc has 2 OSHA inspections on record in Indiana, the first in 2014.

OSHA's last visit started on Feb 9, 2021 after a complaint, in Cloverdale.

Across those inspections OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

OSHA proposed $9,750 in penalties. After settlements and reviews the total is $2,160, down 78%.

Most often, OSHA cited 1910.106, flammable liquids (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Scorpion Protective Coatings Inc averages $1,560 over 1 cited inspection in that time.

Scorpion Protective Coatings Inc: OSHA citation items per year, 2014 to 2021
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Scorpion Protective Coatings Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345142764 OPENED FEB 9, 2021Closed

Complaint · Partial · Health · 16 employees at the site · Closed Oct 18, 2024

6184 South Us Hwy 231, Cloverdale, IN 46120 · Photographic Film, Paper, Plate, Chemical, and Copy Toner Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$1,500$975Dec 10, 2021Final
Citation 1, item 1b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Dec 10, 2021Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$600$390Dec 10, 2021Final
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$300$195Dec 10, 2021Final

Inspection 317451433 OPENED MAR 20, 2014Closed

Complaint · Partial · Health · 25 employees at the site · Closed Feb 6, 2015

6184 South Us Highway 231, Cloverdale, IN 46120 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(3)(iii) · Flammable liquids
Serious$1,050$100Jun 10, 2014Closed
Citation 1, item 2
29 CFR 1910.106(e)(3)(iva) · Flammable liquids
Serious$1,050$100Jun 10, 2014Closed
Citation 1, item 3
29 CFR 1910.106(e)(3)(v)(a) · Flammable liquids
Serious$1,500$100Jun 10, 2014Closed
Citation 1, item 4
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,500$100Jun 10, 2014Closed
Citation 1, item 5
29 CFR 1910.106(e)(7)(i)(b) · Flammable liquids
Serious$1,500$100Jun 10, 2014Closed
Citation 1, item 6
29 CFR 1910.106(h)(4)(iv)(a) · Flammable liquids
Serious$750$100Jun 10, 2014Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(3)(iii)

(iii) Chemical processes. Areas where unstable liquids are handled or small scale unit chemical processes are carried on shall be separated from the remainder of the plant by a fire wall of 2-hour minimum fire resistance rating.

29 CFR 1910.106(e)(3)(iva)

(iv) Drainage. (a) Emergency drainage systems shall be provided to direct flammable liquid leakage and fire protection water to a safe location. This may require curbs, scuppers, or special drainage systems to control the spread of fire; see paragraph (b)(2)(vii)(b) of this section.

29 CFR 1910.106(e)(3)(v)(a)

(v) Ventilation—(a) Areas as defined in paragraph (e)(3)(i) of this section using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area. This shall be accomplished by natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building. Provision shall be made for introduction of makeup air in such a manner as not to short circuit the ventilation. Ventilation shall be arranged to include all floor areas or pits where flammable vapors may collect.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.303 · Electrical equipment, general requirements

Other metal coating, engraving (except jewelry and silverware), and allied services to manufacturers employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.