OSHA SearchOSHA records by employer

Scotland Hardwoods, LLC: OSHA inspections and violations

Scotland, Connecticut · Sawmills · NAICS 321113

1inspections
3citation items
$6,000current penalties
Jul 6, 2017last inspection

OSHA inspectors have visited Scotland Hardwoods, LLC in Connecticut one time.

It opened on Jul 6, 2017 as a planned inspection, in Scotland.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $11,367; today they stand at $6,000, 47% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Scotland Hardwoods, LLC averages $6,000 across 1 cited inspection.

Scotland Hardwoods, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

89employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Scotland Hardwoods, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342446937 OPENED JUL 6, 2017Closed

Planned · Complete · Safety · 30 employees at the site · Closed Aug 2, 2017

117 Ziegler Road, Scotland, CT 06264 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$4,310$2,000Jul 11, 2017Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(iii) · Electrical equipment, general requirements
Serious$4,310$2,000Jul 11, 2017Final
Citation 1, item 3
29 CFR 1910.304(g)(6)(vi)(c)(8) · Grounding and circuit protection
Serious$2,747$2,000Jul 11, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.265 · Sawmills

29 CFR 1910.265(c)(5)(ii)

(ii) Handrails. Stairways shall be provided with a standard handrail on at least one side or on any open side. Where stairs are more than four feet wide there shall be a standard handrail at each side, and where more than eight feet wide, a third standard handrail shall be erected in the center of the stairway.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iii)

(iii) Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, may not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(6)(vi)(c)(8)

(C) If the equipment is of the following types:

Other sawmills employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.