OSHA SearchOSHA records by employer

Scott Jenkins: OSHA inspections and violations

Tyler, Texas · Framing Contractors · NAICS 238130

1inspections
4citation items
$5,205current penalties
Jun 8, 2020last inspection

OSHA inspectors have visited Scott Jenkins in Texas one time.

It opened on Jun 8, 2020 as a planned inspection, in Tyler.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $13,880; today they stand at $5,205, 62% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Scott Jenkins averages $5,205 across 1 cited inspection.

Scott Jenkins: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Scott Jenkins again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344778089 OPENED JUN 8, 2020Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 29, 2021

1901-3 Stonecrest Blvd., Tyler, TX 75707 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$2,892$1,446Jun 17, 2020Final
Citation 1, item 2a
29 CFR 1926.403(b)(1)(ii) · Electrical equipment on job sites
Serious$3,470$1,735Jun 17, 2020Final
Citation 1, item 2b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$3,470$0Jun 17, 2020Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,048$2,024Jun 17, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(ii)

(ii) Mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.