OSHA SearchOSHA records by employer

Sea Ranch Technologies II, Inc.: OSHA inspections and violations

Jupiter, Florida · Finish Carpentry Contractors · NAICS 238350

1inspections
3citation items
$4,900current penalties
Nov 10, 2015last inspection

Sea Ranch Technologies II, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Nov 10, 2015 as part of a related case, in Jupiter.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $9,800 in penalties. After settlements and reviews the total is $4,900, down 50%.

Most often, OSHA cited 1926.1052, stairways in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sea Ranch Technologies II, Inc. averages $4,900 over 1 cited inspection in that time.

Sea Ranch Technologies II, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Sea Ranch Technologies II, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341047454 OPENED NOV 10, 2015Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Sep 19, 2018

103 Quayside Drive, Jupiter, FL 33477 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$4,900$2,450Nov 23, 2015Final
Citation 1, item 1b
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$0$0Nov 23, 2015Final
Citation 1, item 2
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$4,900$2,450Nov 23, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

Other finish carpentry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.