OSHA SearchOSHA records by employer

Seabreeze Aluminum Culvert, Inc.: OSHA inspections and violations

Stowell, Texas · Fabricated Pipe and Pipe Fitting Manufacturing · NAICS 332996

2inspections
9citation items
$30,142current penalties
May 30, 2024last inspection

Since 2024, OSHA inspectors have visited Seabreeze Aluminum Culvert, Inc. in Texas 2 times.

The most recent inspection opened on May 30, 2024 to follow up on an earlier case, in Stowell.

In all, OSHA issued 9 citation items: 9 serious.

The penalties, $30,142 in total, stand where OSHA first set them.

The rule cited most here is 1910.157 (portable fire extinguishers), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Seabreeze Aluminum Culvert, Inc. averages $15,071 across 2 cited inspections.

Seabreeze Aluminum Culvert, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Seabreeze Aluminum Culvert, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347514580 OPENED MAY 30, 2024Closed

Follow-up · Partial · Safety · 22 employees at the site · Closed Apr 21, 2025

3836 Texas 124, Stowell, TX 77661 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.29(b)(2) · Fall protection systems in general industry
Serious$4,056$4,056Jul 23, 2024Final
Citation 1, item 2
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$3,042$3,042Jul 23, 2024Final

Inspection 347234015 OPENED JAN 25, 2024Closed

Planned · Partial · Safety · 22 employees at the site · Closed Dec 30, 2024

3836 Texas 124, Stowell, TX 77661 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Ladders in general industry
Serious$3,687$3,687Feb 14, 2024Final
Citation 1, item 2a
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$2,765$2,765Feb 14, 2024Final
Citation 1, item 2b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$0$0Feb 14, 2024Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$6,452$6,452Feb 14, 2024Final
Citation 1, item 4
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$2,765$2,765Feb 14, 2024Final
Citation 1, item 5
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$4,610$4,610Feb 14, 2024Final
Citation 1, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,765$2,765Feb 14, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(4)

(4) The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use.

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.305 · Electrical wiring methods

Other fabricated pipe and pipe fitting manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.