Seal Caulk and Waterproofing, LLC: OSHA inspections and violations

Suitland, Maryland · Glass and Glazing Contractors · NAICS 238150

1inspections
2citation items
$1,050current penalties
Mar 13, 2019last inspection

OSHA inspectors have visited Seal Caulk and Waterproofing, LLC in Maryland one time.

It opened on Mar 13, 2019 as a planned inspection, in Suitland.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $1,050 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Seal Caulk and Waterproofing, LLC averages $1,050 across 1 cited inspection.

Seal Caulk and Waterproofing, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

183employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Seal Caulk and Waterproofing, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343858684 OPENED MAR 13, 2019Closed

Planned · Complete · Safety · 12 employees at the site · Closed Oct 21, 2019

Capital Gateway Drive Town Center At Camp Spring, Suitland, MD 20746 · Glass and Glazing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(d)(5)(iii) · Scaffolds, general requirements
Serious$1,050$1,050May 7, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(3)(i) · Scaffolds, general requirements
Serious$0$0May 7, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(5)(iii)

(iii) Secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks shall be installed and secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit.

29 CFR 1926.451(g)(3)(i)

(i) When vertical lifelines are used, they shall be fastened to a fixed safe point of anchorage, shall be independent of the scaffold, and shall be protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights.

Other glass and glazing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.