OSHA SearchOSHA records by employer

Seaport Masonry, Inc.: OSHA inspections and violations

Warwick, Rhode Island · Masonry Contractors · NAICS 238140

1inspections
13citation items
$15,314current penalties
Aug 4, 2022last inspection

Seaport Masonry, Inc. has one OSHA inspection on record in Rhode Island.

OSHA opened it on Aug 4, 2022 after a complaint, in Warwick.

From that inspection OSHA issued 13 citation items: 13 serious.

OSHA proposed $25,524 in penalties. After settlements and reviews the total is $15,314, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Seaport Masonry, Inc. averages $15,314 over 1 cited inspection in that time.

Seaport Masonry, Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

81employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Seaport Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346125057 OPENED AUG 4, 2022Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Dec 17, 2024

1221 Post Road, Warwick, RI 02888 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c) · Respiratory protection
Serious$4,558$2,735Dec 5, 2022Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Dec 5, 2022Final
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Dec 5, 2022Final
Citation 1, item 1d
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Dec 5, 2022Final
Citation 1, item 2a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$6,381$3,829Dec 5, 2022Final
Citation 1, item 2b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Dec 5, 2022Final
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Dec 5, 2022Final
Citation 1, item 2d
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Dec 5, 2022Final
Citation 1, item 2e
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$0$0Dec 5, 2022Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$6,381$3,829Dec 5, 2022Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$3,646$2,188Dec 5, 2022Final
Citation 1, item 5a
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$4,558$2,735Dec 5, 2022Final
Citation 1, item 5b
29 CFR 1926.1153(e)(2) · Silica dust in construction
Serious$0$0Dec 5, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)

(c) After completing the test exercises, the test administrator must question each test subject regarding the comfort of the respirator. When a test subject states that the respirator is unacceptable, the employer must ensure that the test administrator repeats the protocol using another respirator model.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.