OSHA SearchOSHA records by employer

Seaside Waste Services Inc.: OSHA inspections and violations

Hammonton, New Jersey · Solid Waste Collection · NAICS 562111

1inspections
10citation items
$18,000current penalties
Apr 8, 2025last inspection

OSHA has inspected Seaside Waste Services Inc. once in New Jersey.

The inspection began on Apr 8, 2025 after a complaint, in Hammonton.

That inspection ended with 10 citation items: 6 serious and 4 other-than-serious.

Penalties were first proposed at $31,920 and now stand at $18,000, 44% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for staffing, cleaning and waste services employers since 2015 is $2,217, and Seaside Waste Services Inc. averages $18,000 (1 cited inspection).

Seaside Waste Services Inc.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Seaside Waste Services Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348164328 OPENED APR 8, 2025Closed

Complaint · Partial · Safety · 90 employees at the site · Closed Aug 15, 2025

253 N. White Horse Pike, Hammonton, NJ 08037 · Solid Waste Collection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$6,384$3,600Jun 25, 2025Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Jun 25, 2025Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$6,384$3,600Jun 25, 2025Final
Citation 1, item 2b
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Jun 25, 2025Final
Citation 1, item 3
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$10,641$6,000Jun 25, 2025Final
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$8,511$4,800Jun 25, 2025Final
Citation 2, item 1
29 CFR 1910.22(a)(3) · Walking-working surfaces
Other-than-serious$0$0Jun 25, 2025Final
Citation 2, item 2
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Jun 25, 2025Final
Citation 2, item 3
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Jun 25, 2025Final
Citation 2, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jun 25, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

Other solid waste collection employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.