OSHA SearchOSHA records by employer

Sebastian Masonry, LLC: OSHA inspections and violations

Charlotte, North Carolina · Masonry Contractors · NAICS 238140

1inspections
6citation items
$4,410current penalties
May 11, 2021last inspection

Sebastian Masonry, LLC has one OSHA inspection on record in North Carolina.

OSHA opened it on May 11, 2021 as a planned inspection, in Charlotte.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $6,300 in penalties. After settlements and reviews the total is $4,410, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sebastian Masonry, LLC averages $4,410 over 1 cited inspection in that time.

Sebastian Masonry, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Sebastian Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345300636 OPENED MAY 11, 2021Closed

Planned · Partial · Safety · 6 employees at the site · Closed Mar 14, 2025

Darlington Manor, Charlotte, NC 28211 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,100$1,470Aug 20, 2021Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Aug 20, 2021Final
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 20, 2021Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,100$1,470Aug 20, 2021Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,100$1,470Aug 20, 2021Final
Citation 1, item 3b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 20, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.