OSHA SearchOSHA records by employer

Select Plastering Corporation: OSHA inspections and violations

Green Bay, Wisconsin · Drywall and Insulation Contractors · NAICS 238310

7inspections
16citation items
$7,885current penalties
May 4, 2016last inspection

Select Plastering Corporation has 7 OSHA inspections on record in Wisconsin, the first in 2004.

OSHA's last visit started on May 4, 2016 as a planned inspection, in Appleton.

Across those inspections OSHA issued 16 citation items: 13 serious, 1 repeat and 2 other-than-serious.

OSHA proposed $12,150 in penalties. After settlements and reviews the total is $7,885, down 35%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (11 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Select Plastering Corporation averages $0 over 1 cited inspection in that time.

Select Plastering Corporation: OSHA citation items per year, 2004 to 2016
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Select Plastering Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341447753 OPENED MAY 4, 2016Closed

Planned · Partial · Safety · 9 employees at the site · Closed Mar 31, 2017

E Highpond Crossing & N Smoketree Pass, Appleton, WI 54913 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$0$0Jul 22, 2016Final
Citation 1, item 2
29 CFR 1926.454(c)(3) · Scaffold training
Other-than-serious$0$0Jul 22, 2016Final

Inspection 312560444 OPENED FEB 24, 2011Closed

Planned · Partial · Safety · 18 employees at the site · Closed Oct 27, 2014

1110 Midway Rd., Menasha, WI 54952 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(6)(i) · Scaffolds, general requirements
Serious$3,300$1,650May 16, 2011Closed
Citation 1, item 1b
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$0$0May 16, 2011Closed

Inspection 312553233 OPENED AUG 31, 2009Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 16, 2009

2250 Holmgren Way, Green Bay, WI 54304 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$450Sep 10, 2009Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$750$450Sep 10, 2009Closed

Inspection 309842854 OPENED JUL 10, 2008Closed

Planned · Partial · Safety · 17 employees at the site · Closed Sep 16, 2008

3000 Apple Hill Blvd, Appleton, WI 54915 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,800$1,800Aug 20, 2008Closed
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Aug 20, 2008Closed

Inspection 309839827 OPENED AUG 24, 2007Closed

Planned · Partial · Safety · 25 employees at the site · Closed Aug 24, 2007

495 Pearl Avenue, Oshkosh, WI 54903 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306800673 OPENED JUL 28, 2005Closed

Planned · Partial · Safety · 13 employees at the site · Closed Oct 24, 2005

Lime Klin Rd And Gv, Green Bay, WI 54301 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,000$550Sep 27, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 27, 2005Closed
Citation 2, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$1,200Sep 27, 2005Closed
Citation 2, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$0$0Sep 27, 2005Closed

Inspection 306797283 OPENED OCT 1, 2004Closed

Unprogrammed other · Partial · Safety · 12 employees at the site · Closed Nov 18, 2004

Lime Klin Rd And Gv, Green Bay, WI 54301 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$735Oct 19, 2004Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Oct 19, 2004Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$750$525Oct 19, 2004Closed
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$750$525Oct 19, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other drywall and insulation contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.