OSHA SearchOSHA records by employer

Selfridge Plating Inc: OSHA inspections and violations

Mt Clemens, Michigan · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

6inspections
27citation items
$3,890current penalties
Jan 13, 2026last inspection

OSHA has inspected Selfridge Plating Inc 6 times in Michigan since 1996.

The latest one began on Jan 13, 2026 after a complaint, in Harrison Township; the case is still open.

Those inspections ended with 27 citation items: 7 serious and 20 other-than-serious.

Penalties were first proposed at $6,150 and now stand at $3,890, 37% lower after settlements or reviews.

Permit-required confined spaces comes up most often in these citations: 3 items under 1910.146.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Selfridge Plating Inc averages $1,750 (1 cited inspection).

Selfridge Plating Inc also files yearly injury logs with OSHA, summarized below.

Selfridge Plating Inc: OSHA citation items per year, 1996 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Selfridge Plating Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348683525 OPENED JAN 13, 2026Open

Complaint · Partial · Health · 40 employees at the site · Open

42081 Irwin Drive, Harrison Township, MI 48045 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(2) · Respiratory protection
Serious$1,500$750Mar 3, 2026Final
Citation 1, item 1b
29 CFR 1910.134(h)(2) · Respiratory protection
Serious$0$0Mar 3, 2026Final
Citation 1, item 2
29 CFR 408.12153(2)
Serious$1,500$750Mar 3, 2026Final
Citation 2, item 1a
29 CFR 408.14961
Other-than-serious$0$0Mar 3, 2026Final
Citation 2, item 1b
29 CFR 408.14965(1)
Other-than-serious$0$0Mar 3, 2026Final
Citation 3, item 1
29 CFR 408.22141(1)
Other-than-serious$500$250Mar 3, 2026Final

Inspection 312079510 OPENED DEC 14, 2010Closed

Unprogrammed related · Complete · Health · 35 employees at the site · Closed Mar 7, 2011

42081 Irwin Rd, Mt Clemens, MI 48045 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Other-than-serious$0$0Feb 15, 2011Closed
Citation 1, item 1b Other-than-serious$0$0Feb 15, 2011Closed
Citation 1, item 2 Other-than-serious$0$0Feb 15, 2011Closed
Citation 1, item 3
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Feb 15, 2011Closed
Citation 1, item 4
29 CFR 1910.134(c)(2) · Respiratory protection
Other-than-serious$0$0Feb 15, 2011Closed
Citation 1, item 5 Other-than-serious$0$0Feb 15, 2011Closed

Inspection 312041676 OPENED NOV 30, 2010Closed

Planned · Partial · Health · 35 employees at the site · Closed Mar 14, 2011

42081 Irwin Rd, Mt Clemens, MI 48045 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$600$240Feb 17, 2011Closed

Inspection 308811421 OPENED JUL 29, 2008Closed

Planned · No inspection · Health · 34 employees at the site · Closed Jul 29, 2008

42081 Irwin Rd, Mt Clemens, MI 48045 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 127061836 OPENED DEC 12, 2003Closed

Planned · Complete · Safety · 38 employees at the site · Closed Apr 19, 2004

42081 Irwin Rd, Mt Clemens, MI 48045 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$150Feb 26, 2004Closed
Citation 2, item 1 Other-than-serious$0$0Feb 26, 2004Closed
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 26, 2004Closed
Citation 2, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 26, 2004Closed
Citation 2, item 4
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 26, 2004Closed

Inspection 125154492 OPENED NOV 27, 1996Closed

Planned · Complete · Health · 60 employees at the site · Closed May 1, 1997

42081 Irwin, Harrison Twp, MI 48045 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR R322009 D
Serious$875$875Feb 18, 1997Closed
Citation 1, item 2
29 CFR R330301 C
Serious$875$875Feb 18, 1997Closed
Citation 2, item 1a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Feb 18, 1997Closed
Citation 2, item 1b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Feb 18, 1997Closed
Citation 2, item 1c
29 CFR 1910.146(c)(3) · Permit-required confined spaces
Other-than-serious$0$0Feb 18, 1997Closed
Citation 2, item 2
29 CFR R322009 E
Other-than-serious$0$0Feb 18, 1997Closed
Citation 2, item 3a Other-than-serious$0$0Feb 18, 1997Closed
Citation 2, item 3b Other-than-serious$0$0Feb 18, 1997Closed
Citation 2, item 4
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Feb 18, 1997Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Harrison Twp site logged 0 recordable injuries or illnesses among about 44 workers: 0.0 per 100 full-time workers, against a median of 3.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Selfridge Plating, Inc.
Harrison Twp · 2025
44 000.03.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.1200(f)(5)(ii)

(ii) The label for bulk shipments of hazardous chemicals must be on the immediate container, transmitted with the shipping papers or the bills of lading, or, with the agreement of the receiving entity, transmitted by technological or electronic means so that it is immediately available to workers in printed form on the receiving end of shipment.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)

(2) A record of the test shall be kept on file, assuming the fit test was successful. The record must contain the test subject's name; overall fit factor; make, model, style and size of respirator used; and date tested.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 3254.7201

29 CFR 3255.1454

29 CFR 3255.1464

29 CFR 3255.1473

29 CFR 3256.5

29 CFR 3256.8

29 CFR 4081.215

29 CFR 4081.33

Other electroplating, plating, polishing, anodizing, and coloring employers in Michigan