OSHA SearchOSHA records by employer

Seneca Steel Erectors Inc: OSHA inspections and violations

Buffalo, New York · Structural Steel and Precast Concrete Contractors · NAICS 238120

13inspections
10citation items
$4,858current penalties
Aug 20, 2025last inspection

Since 1999, OSHA inspectors have visited Seneca Steel Erectors Inc in New York 13 times.

The most recent inspection opened on Aug 20, 2025, in Niagara Falls.

In all, OSHA issued 10 citation items: 6 serious and 4 other-than-serious.

The proposed penalties came to $7,542; today they stand at $4,858, 36% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Seneca Steel Erectors Inc averages $1,000 across 1 cited inspection.

Seneca Steel Erectors Inc: OSHA citation items per year, 1999 to 2025
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Seneca Steel Erectors Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348454018 OPENED AUG 20, 2025Closed

Programmed other · Partial · Safety · 9 employees at the site · Closed Nov 20, 2025

Bldg 917 Niagara Falls Air Force Reserve Wing, Niagara Falls, NY 14301 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$1,809$1,000Sep 4, 2025Final

Inspection 341347128 OPENED MAR 18, 2016Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Oct 6, 2016

John R. Oishei Children?s Hospital High Street, Buffalo, NY 14203 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339922114 OPENED AUG 26, 2014Closed

Referral · Partial · Safety · 30 employees at the site · Closed May 12, 2015

250 Delaware Avenue, Buffalo, NY 14202 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316089465 OPENED NOV 30, 2011Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Jul 23, 2012

1300 Elmwood Avenue (new Technology Building), Buffalo, NY 14222 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312400831 OPENED AUG 6, 2008Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 28, 2008

374 Lake Street, Wilson, NY 14172 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$637$637Aug 21, 2008Closed

Inspection 308530005 OPENED FEB 1, 2005Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 19, 2005

Canisius College Main Campus Residence Hall, Buffalo, NY 14208 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,050Mar 4, 2005Closed
Citation 1, item 2
29 CFR 1926.502(d)(11) · Fall protection systems
Serious$750$525Mar 4, 2005Closed

Inspection 307475335 OPENED MAR 15, 2004Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jun 25, 2004

45 Elm Street, Buffalo, NY 14203 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(b)(1) · Stairways in construction
Other-than-serious$446$446Mar 24, 2004Closed

Inspection 306895624 OPENED AUG 19, 2003Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 19, 2003

Military & Upper Mountain Road, Lewiston, NY 14092 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

5 older inspections

Inspection 306470998 OPENED JUN 18, 2003Closed

Planned · Complete · Safety · 7 employees at the site · Closed Sep 20, 2003

Ketter Hall, Sunyab, Buffalo, NY 14214 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.352(d) · Fire prevention
Other-than-serious$0$0Sep 4, 2003Closed

Inspection 108660747 OPENED JUN 11, 2002Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Nov 22, 2002

290 N. Buffalo Street, Springville, NY 14141 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Other-than-serious$1,200$0Aug 2, 2002Final

Inspection 304075971 OPENED JAN 18, 2001Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Feb 16, 2001

646 Main Street, Buffalo, NY 14202 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108950072 OPENED JUN 27, 2000Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 29, 2000

Buffalo Airport Parking Lot, 4200 Genesee Street, Cheektowaga, NY 14225 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Jul 27, 2000Closed

Inspection 301006722 OPENED APR 21, 1999Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jul 16, 1999

Military & Upper Mountain Road, Lewiston, NY 14092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.104(b) · Safety belts, lifelines, and lanyards
Serious$600$600Jun 17, 1999Closed
Citation 1, item 2
29 CFR 1926.104(d) · Safety belts, lifelines, and lanyards
Serious$600$600Jun 17, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.104 · Safety belts, lifelines, and lanyards

29 CFR 1926.104(b)

(b) Lifelines shall be secured above the point of operation to an anchorage or structural member capable of supporting a minimum dead weight of 5,400 pounds.

29 CFR 1926.104(d)

(d) Safety belt lanyard shall be a minimum of 1/2-inch nylon, or equivalent, with a maximum length to provide for a fall of no greater than 6 feet. The rope shall have a nominal breaking strength of 5,400 pounds.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.352 · Fire prevention

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.