Sergio Antonio Agostin Hernandez: OSHA inspections and violations

Smyrna, Georgia · Masonry Contractors · NAICS 238140

1inspections
2citation items
$7,518current penalties
Feb 19, 2020last inspection

Sergio Antonio Agostin Hernandez has one OSHA inspection on record in Georgia.

OSHA opened it on Feb 19, 2020 as a planned inspection, in Smyrna.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,518 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sergio Antonio Agostin Hernandez averages $7,518 over 1 cited inspection in that time.

Sergio Antonio Agostin Hernandez: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Sergio Antonio Agostin Hernandez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344638796 OPENED FEB 19, 2020Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 27, 2023

(lot #10) 2873 Elmwood Drive, Smyrna, GA 30080 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,470$3,470Mar 16, 2020Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,048$4,048Mar 16, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other masonry contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.