OSHA SearchOSHA records by employer

Sergio Flores: OSHA inspections and violations

Richmond, Texas · Framing Contractors · NAICS 238130

2inspections
4citation items
$13,741current penalties
Mar 19, 2021last inspection

Sergio Flores has 2 OSHA inspections on record in Texas, the first in 2011.

OSHA's last visit started on Mar 19, 2021 as a planned inspection, in Lubbock.

Across those inspections OSHA issued 4 citation items: 4 serious.

OSHA proposed $13,741 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Sergio Flores averages $2,341 over 1 cited inspection in that time.

Sergio Flores: OSHA citation items per year, 2011 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Sergio Flores again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345207278 OPENED MAR 19, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 15, 2024

3901 114th St, Lubbock, TX 79424 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,341$2,341Apr 27, 2021Final

Inspection 315723262 OPENED NOV 8, 2011Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 1, 2013

6626 White Hill Lane, Richmond, TX 77046 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$3,600$3,600Nov 30, 2011Closed
Citation 1, item 2
29 CFR 1926.451(f)(2) · Scaffolds, general requirements
Serious$4,200$4,200Nov 30, 2011Closed
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,600$3,600Nov 30, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(2)

(2) The use of shore or lean-to scaffolds is prohibited.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other framing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.