Serven Volunteer Fire Company: OSHA inspections and violations

Waterloo, New York · Fire Protection · NAICS 922160

5inspections
8citation items
$0current penalties
Aug 27, 2024last inspection

Serven Volunteer Fire Company has 5 OSHA inspections on record in New York, the first in 2024.

OSHA's last visit started on Aug 27, 2024 to follow up on an earlier case, in Waterloo.

Across those inspections OSHA issued 8 citation items: 7 serious and 1 repeat.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.156, fire brigades (4 items).

For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. Serven Volunteer Fire Company averages $0 over 2 cited inspections in that time.

Serven Volunteer Fire Company: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

376employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Serven Volunteer Fire Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347714545 OPENED AUG 27, 2024Closed

Follow-up · Records only · Safety · Local government · 20 employees at the site · Closed Aug 27, 2024

352 Us Route 20, Waterloo, NY 13165 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347716276 OPENED AUG 15, 2024Closed

Follow-up · Partial · Health · Local government · 20 employees at the site · Closed Sep 16, 2024

352 Us Route 20, Waterloo, NY 13165 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347707069 OPENED JUL 29, 2024Closed

Monitoring · Partial · Safety · Local government · 20 employees at the site · Closed Jul 29, 2024

352 Us Route 20, Waterloo, NY 13165 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347636805 OPENED JUL 17, 2024Closed

Referral · Partial · Health · Local government · 20 employees at the site · Closed Sep 17, 2024

352 Us Route 20, Waterloo, NY 13165 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$0$0Aug 7, 2024Final
Citation 1, item 2
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Aug 7, 2024Final

Inspection 347493009 OPENED MAY 20, 2024Closed

Complaint · Partial · Safety · Local government · 20 employees at the site · Closed Aug 27, 2024

352 Us Route 20, Waterloo, NY 13165 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 12 NYCRR PART 800.7(F)(1)
Serious$0$0Jul 3, 2024Final
Citation 1, item 2
29 CFR 1910.120(p)(8)(i) · Hazardous waste operations and emergency response
Serious$0$0Jul 3, 2024Final
Citation 1, item 3
29 CFR 1910.156(c)(1) · Fire brigades
Serious$0$0Jul 3, 2024Final
Citation 1, item 4
29 CFR 1910.156(c)(2) · Fire brigades
Serious$0$0Jul 3, 2024Final
Citation 1, item 5
29 CFR 1910.156(d) · Fire brigades
Serious$0$0Jul 3, 2024Final
Citation 2, item 1
29 CFR 1910.156(c)(1) · Fire brigades
Repeat$0$0Jul 3, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.120(p)(8)(i)

(8) Emergency response program—(i) Emergency response plan. An emergency response plan shall be developed and implemented by all employers. Such plans need not duplicate any of the subjects fully addressed in the employer's contingency planning required by permits, such as those issued by the U.S. Environmental Protection Agency, provided that the contingency plan is made part of the emergency response plan. The emergency response plan shall be a written portion of the employer's safety and health program required in paragraph (p)(1) of this section. Employers who will evacuate their employees from the worksite location when an emergency occurs and who do not permit any of their employees to assist in handling the emergency are exempt from the requirements of paragraph (p)(8) if they provide an emergency action plan complying with 29 CFR 1910.38.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.156 · Fire brigades

Other fire protection employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.