Inspection 348101510 OPENED MAR 12, 2025Closed
301 & 315 Tyler Avenue, Radford, VA 24142 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1985, OSHA inspectors have visited Service Contracting of VA., Inc. in Virginia 26 times.
The most recent inspection opened on Mar 12, 2025 as a planned inspection, in Radford.
In all, OSHA issued 14 citation items: 7 serious and 7 other-than-serious.
The proposed penalties came to $13,725; today they stand at $8,716, 36% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Service Contracting of VA., Inc. averages $1,694 across 4 cited inspections.
Virginia · latest 90 days of OSHA records
254employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Service Contracting of VA., Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company301 & 315 Tyler Avenue, Radford, VA 24142 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
281 Bagley Circle, Marion, VA 24354 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Apr 30, 2025 | Final |
723 West Main Street, Radford, VA 24141 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $4,540 | $3,178 | Jun 6, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(4) · Ladders in construction |
Serious | $3,460 | $2,422 | Jun 6, 2022 | Final |
Session Hotel 833 State Street, Bristol, VA 24201 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Bluefield College Science Building, Bluefield, VA 24605 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1 Health Way, Marion, VA 24354 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.34(c) · Means of egress |
Other-than-serious | $1,680 | $1,176 | Jun 20, 2016 | Final |
Pocahontas & Bolling Halls @ Ru, Radford, VA 24141 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Other-than-serious | $980 | $0 | Apr 13, 2015 | Final |
3901 Old Forest Rd, Lynchburg, VA 24501 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1142 Highland Drive, Marion, VA 24354 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
143 3rd Street Nw, Pulaski, VA 24301 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Russell Hall, Cedar Bluff, VA 24609 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4880 Brambleton Ave., Roanoke, VA 24018 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8561 Roanoke Rd., Shawsville, VA 24087 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Duckpond & Washington Street, Blacksburg, VA 24060 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Other-than-serious | $1,125 | $0 | Aug 20, 2009 | Final |
802 2nd Avenue, Radford, VA 24141 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
802 2nd Avenue, Radford, VA 24141 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Russell Hall Radford University, Radford, VA 24141 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Russell Hall Radford University, Radford, VA 24141 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Effinger Elementary School, Lexington, VA 24450 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 27, 2005 | Closed |
Malin Drive, Wytheville, VA 24382 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Va-tech Vet Ctr. Duck Pond Rd., Blacksburg, VA 24061 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $1,100 | $1,100 | Sep 21, 1994 | Closed |
| Citation 1, item 1b 29 CFR 1926.405(a)(2)(ii)(1) · Job-site wiring |
Serious | $0 | $0 | Sep 21, 1994 | Closed |
Tyler Hall Radford University, Radford, VA 24142 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.50(c) · Medical services and first aid |
Other-than-serious | $0 | $0 | Sep 1, 1993 | Closed |
| Citation 1, item 2 29 CFR 1926.51(f) · Sanitation |
Other-than-serious | $0 | $0 | Sep 1, 1993 | Closed |
2522 Orange Rd, A.g. Richardson Elementary School, Culpeper, VA 22701 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
22 E. Main St., Bedford, VA 24523 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
J.m.u., College Of Business, Bluestone Drive, Harrisonburg, VA 22801 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rucker Street & Rye Cove Road, Stuart, VA 24171 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(a)(4) · Scaffolds, general requirements |
Serious | $420 | $420 | Dec 4, 1985 | Closed |
| Citation 1, item 2a 29 CFR 1926.451(a)(15) · Scaffolds, general requirements |
Serious | $420 | $420 | Dec 4, 1985 | Closed |
| Citation 1, item 2b 29 CFR 1926.451(d)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Dec 4, 1985 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)
29 CFR 1926.1053(b)(4)
(4) Ladders shall be used only for the purpose for which they were designed.
29 CFR 1926.34(c)
(c) Maintenance and workmanship. Means of egress shall be continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.