The inspection began on Feb 2, 2017 on a referral, in Louisville.
That inspection ended with 2 citation items: 1 serious and 1 other-than-serious.
Penalties were first proposed at $1,000 and still stand at $6,387.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Servtech averages $6,387 (1 cited inspection).
Servtech also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Want to know if OSHA cites Servtech again? Add it to a watchlist and we will email you the morning the citation shows up.
Incident on Jan 19, 2017: Employee's little finger is caught by hydraulic clamp and is
At approximately 10:30 a.m. on January 19, 2017, Employee #1 was operating a CNC Drill-Line machine that drills holes in structural steel. He moved pieces of metal while the machine was still operating. As he positioned one of the metal pieces, his hand was caught in a hydraulic clamp, which would hold down the metal piece as it was being cut. The clamp amputated his right little finger, just below first knuckle. Employee #1 was transported to a medical center, where he received treatment and was then hospitalized.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Louisville site logged 0 recordable injuries or illnesses among about 108 workers: 0.0 per 100 full-time workers, against a median of 2.7 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Servtech, Inc.
Louisville · 2025
108
0
0
0.0
2.7
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Other switchgear and switchboard apparatus manufacturing employers in Colorado