OSHA SearchOSHA records by employer

Sessions Corporation: OSHA inspections and violations

North Logan, Utah · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
8citation items
$3,150current penalties
Oct 9, 2015last inspection

Sessions Corporation has one OSHA inspection on record in Utah.

OSHA opened it on Oct 9, 2015 as a planned inspection, in North Logan.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA proposed $6,300 in penalties. After settlements and reviews the total is $3,150, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sessions Corporation averages $3,150 over 1 cited inspection in that time.

Sessions Corporation: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Sessions Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340984020 OPENED OCT 9, 2015Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jan 14, 2016

2855 Naomi Dr, North Logan, UT 84341 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$1,050$525Nov 13, 2015Final
Citation 1, item 1b
29 CFR 1926.405(g)(2) · Job-site wiring
Serious$0$0Nov 13, 2015Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$750Nov 13, 2015Final
Citation 1, item 2b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Nov 13, 2015Final
Citation 1, item 2c
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Nov 13, 2015Final
Citation 1, item 3
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$750Nov 13, 2015Final
Citation 1, item 4
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,500$750Nov 13, 2015Final
Citation 1, item 5
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$750$375Nov 13, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.