Shamrock Technologies, Inc: OSHA inspections and violations
Newark, New Jersey · Commercial and Institutional Building Construction · NAICS 236220
3inspections
9citation items
$9,450current penalties
May 4, 2015last inspection
OSHA has inspected Shamrock Technologies, Inc 3 times in New Jersey since 1997.
The latest one began on May 4, 2015 on a referral, in Newark.
Those inspections ended with 9 citation items: 5 serious and 4 other-than-serious.
Penalties were first proposed at $12,600 and now stand at $9,450, 25% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 2 items under 1910.147.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Shamrock Technologies, Inc averages $7,350 (1 cited inspection).
Shamrock Technologies, Inc also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
New Jersey · latest 90 days of OSHA records
264employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Shamrock Technologies, Inc and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2017, the Newark site logged 4 recordable injuries or illnesses among about 95 workers: 4.0 per 100 full-time workers, against a median of 1.6 for its industry. Those cases cost 183 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Newark site
Newark · 2017
95
4
3
4.0
1.6
Included with any plan: 1 more yearly log from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
29 CFR 1910.1200(h)(3)(ii)
(ii) The physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area;
29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.