OSHA SearchOSHA records by employer

Shelor Motor Mile Inc.: OSHA inspections and violations

Christiansburg, Virginia · Other Services to Buildings and Dwellings · NAICS 561790

5inspections
6citation items
$5,644current penalties
Dec 3, 2025last inspection

Since 2001, OSHA inspectors have visited Shelor Motor Mile Inc. in Virginia 5 times.

The most recent inspection opened on Dec 3, 2025 after a complaint, in Christiansburg.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The proposed penalties came to $10,600; today they stand at $5,644, 47% less.

The rule cited most here is 1910.146 (permit-required confined spaces), 2 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,217 penalty. Shelor Motor Mile Inc. averages $2,822 across 2 cited inspections.

Shelor Motor Mile Inc. also files yearly injury logs with OSHA, summarized below.

Shelor Motor Mile Inc.: OSHA citation items per year, 2001 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Shelor Motor Mile Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348622317 OPENED DEC 3, 2025Closed

Complaint · Partial · Health · 395 employees at the site · Closed Jan 14, 2026

2230 Roanoke Street, Christiansburg, VA 24073 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346665680 OPENED APR 28, 2023Closed

Planned · Complete · Health · 40 employees at the site · Closed Aug 23, 2023

2230 Roanoke Street, Christiansburg, VA 24073 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$6,895$4,100Jun 8, 2023Final
Citation 1, item 1b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$0$0Jun 8, 2023Final
Citation 2, item 1
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Other-than-serious$0$0Jun 8, 2023Final

Inspection 342449162 OPENED JUN 28, 2017Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 11, 2017

1004 E. Main Street, Pulaski, VA 24301 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342171063 OPENED MAR 1, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 21, 2017

7327 Peppers Ferry Blvd., Fairlawn, VA 24141 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$2,205$1,544May 30, 2017Final

Inspection 304775067 OPENED NOV 8, 2001Closed

Planned · Complete · Health · 30 employees at the site · Closed Jan 31, 2002

407 Roanoke Street, Christiansburg, VA 24073 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$1,500$0Nov 30, 2001Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Other-than-serious$0$0Nov 30, 2001Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Christiansburg site logged 7 recordable injuries or illnesses among about 19 workers: 1.4 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Shelor Motor Mile Inc
Christiansburg · 2025
19 701.42.7

Included with any plan: 5 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(1)

(c) General requirements. (1) The employer shall evaluate the workplace to determine if any spaces are permit- required confined spaces.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.305 · Electrical wiring methods

Other other services to buildings and dwellings employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.