OSHA SearchOSHA records by employer

Shingles, Etc., Inc.: OSHA inspections and violations

Waukesha, Wisconsin · Roofing Contractors · NAICS 238160

8inspections
20citation items
$11,170current penalties
Jul 2, 2018last inspection

OSHA has inspected Shingles, Etc., Inc. 8 times in Wisconsin since 2005.

The latest one began on Jul 2, 2018 as a planned inspection, in Bristol.

Those inspections ended with 20 citation items: 20 serious.

Penalties were first proposed at $23,151 and now stand at $11,170, 52% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 7 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Shingles, Etc., Inc. averages $3,000 (1 cited inspection).

Shingles, Etc., Inc.: OSHA citation items per year, 2005 to 2018
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

232employers cited

45 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Shingles, Etc., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343278768 OPENED JUL 2, 2018Closed

Planned · Partial · Safety · 18 employees at the site · Closed Oct 22, 2019

7815 Williamsburg Ct., Bristol, WI 53104 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,434$3,000Sep 28, 2018Final
Citation 1, item 1b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$2,217$0Sep 28, 2018Final

Inspection 334213253 OPENED MAY 4, 2012Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jun 19, 2012

2739 Lincoln Ave, Kenosha, WI 53144 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313528713 OPENED JUL 6, 2010Closed

Planned · Partial · Safety · 15 employees at the site · Closed Jun 3, 2011

3220 Tanglewood Dr., Waukesha, WI 53189 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$800$358Aug 2, 2010Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,000$448Aug 2, 2010Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,000$448Aug 2, 2010Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$800$358Aug 2, 2010Final

Inspection 313528622 OPENED JUN 30, 2010Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jun 3, 2011

S94 W12420 Ryan Rd., Muskego, WI 53150 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$800$358Aug 2, 2010Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$800$358Aug 2, 2010Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$800$358Aug 2, 2010Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$800$359Aug 2, 2010Final

Inspection 313528119 OPENED JUN 2, 2010Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jul 15, 2011

Lot 2 S. 94th St., West Allis, WI 53227 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$1,050$470Aug 2, 2010Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$269Aug 2, 2010Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,050$470Aug 2, 2010Final
Citation 1, item 4
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$1,050$470Aug 2, 2010Final

Inspection 313527897 OPENED MAY 22, 2010Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jul 15, 2011

2954 Nostaloc Ct., Richfield, WI 53076 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$600$268Aug 2, 2010Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$672Aug 2, 2010Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$750$336Aug 2, 2010Final

Inspection 122393598 OPENED JAN 11, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 22, 2007

Heritage Hills Lot 51, 3209 Howell Ct, Waukesha, WI 53188 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$600$420Jan 25, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,000$700Jan 25, 2007Closed

Inspection 307058941 OPENED JAN 7, 2005Closed

Planned · Partial · Safety · 10 employees at the site · Closed Feb 7, 2005

108 Howell Ave., Waukesha, WI 53186 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,050Jan 20, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.