OSHA SearchOSHA records by employer

Shumaker Roofing Company: OSHA inspections and violations

Hagerstown, Maryland · Roofing Contractors · NAICS 238160

3inspections
10citation items
$2,252current penalties
Jan 23, 2023last inspection

Shumaker Roofing Company has 3 OSHA inspections on record in Maryland, the first in 1996.

OSHA's last visit started on Jan 23, 2023 as a planned inspection, in Hagerstown.

Across those inspections OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

OSHA proposed $4,599 in penalties. After settlements and reviews the total is $2,252, down 51%.

Most often, OSHA cited 1926.501, fall protection in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Shumaker Roofing Company averages $812 over 1 cited inspection in that time.

Shumaker Roofing Company: OSHA citation items per year, 1996 to 2023
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Shumaker Roofing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346451719 OPENED JAN 23, 2023Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 12, 2023

351 Center Street, Hagerstown, MD 21740 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$375$375Mar 28, 2023Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$437$437Mar 28, 2023Final

Inspection 309658508 OPENED JAN 9, 2006Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 3, 2006

Rear Of 55 East Franklin Street, Hagerstown, MD 21740 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$900$360Feb 13, 2006Closed
Citation 2, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$900$360Feb 13, 2006Closed
Citation 3, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,050$420Feb 13, 2006Closed
Citation 4, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Feb 13, 2006Closed

Inspection 127372480 OPENED APR 15, 1996Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 29, 1996

118 Key Parkway, Frederick, MD 21702 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$150$100May 21, 1996Closed
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$525$100May 21, 1996Closed
Citation 3, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$262$100May 21, 1996Closed
Citation 4, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0May 21, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.