OSHA SearchOSHA records by employer

Shure-Line Electrical, Inc.: OSHA inspections and violations

New Castle, Delaware · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

6inspections
8citation items
$41,744current penalties
May 1, 2023last inspection

Since 2004, OSHA inspectors have visited Shure-Line Electrical, Inc. in Delaware 6 times.

The most recent inspection opened on May 1, 2023, in Wilmington.

In all, OSHA issued 8 citation items: 3 serious and 5 other-than-serious.

The proposed penalties came to $49,719; today they stand at $41,744, 16% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Shure-Line Electrical, Inc. averages $13,223 across 3 cited inspections.

It reported 1 severe injury to OSHA since 2015.

Shure-Line Electrical, Inc.: OSHA citation items per year, 2004 to 2023
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch Shure-Line Electrical, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346670326 OPENED MAY 1, 2023Closed

Unprogrammed other · Partial · Safety · 12 employees at the site · Closed Sep 14, 2023

400 Mill Road, Wilmington, DE 19806 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Other-than-serious$12,031$9,625Aug 16, 2023Final
Citation 1, item 2
29 CFR 1926.502(b)(2) · Fall protection systems
Other-than-serious$12,031$9,625Aug 16, 2023Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$10,313$8,250Aug 16, 2023Final

Inspection 345225734 OPENED MAR 31, 2021Closed

Unprogrammed other · Partial · Safety · 100 employees at the site · Closed Sep 20, 2021

999 N. Dupont Blvd, Milford, DE 19963 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$8,936$8,936Jun 23, 2021Final

Inspection 341963023 OPENED DEC 9, 2016Closed

Unprogrammed related · Partial · Safety · 7 employees at the site · Closed Mar 1, 2017

701 Water Street The Residences At River Place, Seaford, DE 19973 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$3,233$3,233Jan 31, 2017Final

Inspection 311808174 OPENED MAR 25, 2010Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Apr 19, 2010

419 W. 9th Street, New Castle, DE 19720 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$900$630Apr 8, 2010Closed

Inspection 305945933 OPENED JUN 9, 2004Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Nov 2, 2004

1 Sea Colt Lane, Bethany Beach, DE 19930 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,575$990Oct 14, 2004Closed

Inspection 305945818 OPENED MAY 19, 2004Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jun 21, 2004

419 W. 9th Street, New Castle, DE 19720 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$700$455Jun 4, 2004Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

May 14, 2018, Wilmington: Hospitalization · fractures · wrist(s)

On 05/14/2018, at approximately 2:45 PM, an employee was working from a 12-foot fiberglass A-frame step ladder. The employee was using a drill to install conduit for a junction box when he fell 8-9 feet from the ladder onto the concrete floor below, fracturing his right/left wrists and lacerating his face above the left eye. He was hospitalized for surgery and stitches. Proper PPE was worn at the time.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other electrical contractors and other wiring installation contractors employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.