Inspection 346982259 OPENED SEP 19, 2023Closed
9898 S. 1055 W., South Jordan, UT 84095 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
West Haven, Utah · Masonry Contractors · NAICS 238140
OSHA has inspected Sierra Stucco and Plastering 3 times in Utah since 2008.
The latest one began on Sep 19, 2023 on a referral, in South Jordan.
Those inspections ended with 8 citation items: 7 serious and 1 other-than-serious.
Penalties were first proposed at $3,300 and still stand at $3,300.
Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Sierra Stucco and Plastering averages $3,000 (1 cited inspection).
Utah · latest 90 days of OSHA records
73employers cited
Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Utah
Checking a subcontractor, a client or your own company? Watch Sierra Stucco and Plastering and get notified the morning OSHA posts a new citation for it.
Watch this company9898 S. 1055 W., South Jordan, UT 84095 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Vicinity Of 1383 W 2400 N, Clinton, UT 84015 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $1,500 | $1,500 | Mar 9, 2015 | Final |
| Citation 1, item 1b 29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 9, 2015 | Final |
| Citation 1, item 1c 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 9, 2015 | Final |
| Citation 1, item 1d 29 CFR 1926.451(f)(4) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 9, 2015 | Final |
| Citation 1, item 1e 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 9, 2015 | Final |
| Citation 1, item 1f 29 CFR 1926.452(c)(2) · Rules for each type of scaffold |
Serious | $0 | $0 | Mar 9, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $1,500 | $1,500 | Mar 9, 2015 | Final |
Stone Creek Canyon Development, West Haven, UT 84401 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Other-than-serious | $300 | $300 | Jul 22, 2008 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(c)(2)
(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.
29 CFR 1926.451(c)(2)(i)
(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.
Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.