OSHA SearchOSHA records by employer

Silman Framing, LLC.: OSHA inspections and violations

Killeen, Texas · Framing Contractors · NAICS 238130

1inspections
5citation items
$8,775current penalties
Nov 22, 2021last inspection

OSHA inspectors have visited Silman Framing, LLC. in Texas one time.

It opened on Nov 22, 2021 as a planned inspection, in Killeen.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $8,775 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Silman Framing, LLC. averages $8,775 across 1 cited inspection.

Silman Framing, LLC.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Silman Framing, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345650857 OPENED NOV 22, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 24, 2024

7807 Preston Hollow, Killeen, TX 76542 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,755$1,755Dec 6, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,755$1,755Dec 6, 2021Final
Citation 1, item 3
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,755$1,755Dec 6, 2021Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,755$1,755Dec 6, 2021Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,755$1,755Dec 6, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.