OSHA SearchOSHA records by employer

Silvero Quiroz: OSHA inspections and violations

Fort Worth, Texas · Masonry Contractors · NAICS 238140

1inspections
5citation items
$4,000current penalties
Apr 22, 2015last inspection

Silvero Quiroz has one OSHA inspection on record in Texas.

OSHA opened it on Apr 22, 2015 as a planned inspection, in Fort Worth.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $8,280 in penalties. After settlements and reviews the total is $4,000, down 52%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Silvero Quiroz averages $4,000 over 1 cited inspection in that time.

Silvero Quiroz: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Silvero Quiroz and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340573823 OPENED APR 22, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 19, 2016

8348 Blue Periwinkle Lane Fort Worth Texas, Fort Worth, TX 76123 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,800$900May 1, 2015Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,800$900May 1, 2015Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,800$900May 1, 2015Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$1,800$900May 1, 2015Final
Citation 1, item 5
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$1,080$400May 1, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.